On October 1-4, 2023 OKOndt GROUP attended Railway Interchange 2023 - the largest North American railway event. This time the exhibition took place in Indianapolis, Indiana, USA (Indiana Convention Center) and brought together over 700 exhibitors and more than 8, 000 visitors who are the major influencers in the industry. Thank you to everyone who was with us at the RI 2023!

Eddy current probes

Dynamic Rotating Countersink ECP:

  • typical differential probe built according to the “Reflection” scheme, the sensing element of which is built into the plastic (or rigid wearproof metal) case
  • designed for testing of holes countersink surface of a given diameter (an ECP is selected to a specific countersink angle and a hole guiding diameter)
  • applied together with eddy current rotary scanners SVR-04/SVR-05 (OKOndt Group)
  • compatible with the rotary scanners Mini Mite (OLYMPUS), Mini Drive (GE) and others
  • applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.

Designation

Guide hole diameter “D”,
mm/inch

Countersink

angle, deg

Length,
mm

Frequency

Material

Connector

RCP-100˚- 3.17

3.17/.125

100

64

200 kHz - 3 MHz

Fe/NFe

4-pin Fischer connector

(to Hocking, GE, Rohmann and Forester drive units, etc.)

RCP-100˚- 3.96

3.96/.156

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 4

4/.157

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 4.75

4.75/.187

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 5

5/.197

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 6

6/.236

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 6.34

6.34/.25

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 7

7/.276

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 7.92

7.92/.312

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 9

9/.354

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 9.52

9.52/.375

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 11

11/.433

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 11.09

11.09/.437

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 12.69

12.69/.5

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 13

13/.512

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 14.26

14.26/.562

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 15

15/.59

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 15.86

15.86/.625

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 17.44

17.44/.687

100

64

200 kHz - 3 MHz

Fe/NFe

RCP-100˚- 19.03

19.03/.75

100

64

200 kHz - 3 MHz

Fe/NFe


RCP

-

100˚

-

3.17

(SS/Sh)

1

 

2

 

3

4


  1. RCP – dynamic rotating probe for hole countersinks testing.

  2. Countersink angle, deg

  3. Range of hole size, mm.

  4. Guide hole diameter, mm.

  5. The housing of a standard probe is made of delrin; in case a stainless steel housing is required, please indicate the letters “SS”(Stainless Steel) at the end of a probe designation code in your order.

It is possible to manufacture the probes for countersink testing with other angles. For this, the required countersink angle should be specified in the order.