On October 1-4, 2023 OKOndt GROUP attended Railway Interchange 2023 - the largest North American railway event. This time the exhibition took place in Indianapolis, Indiana, USA (Indiana Convention Center) and brought together over 700 exhibitors and more than 8, 000 visitors who are the major influencers in the industry. Thank you to everyone who was with us at the RI 2023!

Eddy current probes

Manual Rotating ECP with Split Tip for Holes Testing:

  • typical absolute single-coil probe built according to the “Single coil” scheme the sensing element of which is built into the split plastic case
  • designed for manual testing of holes with a specified diameter range
  • applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.

Designation

Tip Ø ‘D’,
mm

Working length
"WL", mm

Length,
mm

Frequency

Connector

Material

ROM3,1-3,6×85/105SS

3,1-3,6

35/51

85/105

200 kHz/500 kHz/

2 MHz

Microdot

Fe/NFe

ROM3,6-4,1×85/105SS

3,6-4,1

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM4,1-4,6×85/105SS

4.1-4.6

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM4,6-5.1×85/105SS

4.6-5.1

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM5,1-5,6×85/105SS

5.1-5.6

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM5,6-6,1×85/105SS

5.6-6.1

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM6.1-6.5×85/105SS

6.1-6.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM6.5-7.5×85/105SS

6.5-7.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM7.5-8.5×85/105SS

7.5-8.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM8.5-9.5×85/105SS

8.5-9.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM9.5-10.5×85/105SS

9.5-10.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM10.5-11.5×85/105SS

10.5-11.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM11.5-12.5×85/105SS

11.5-12.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM12.5-13.5×85/105SS

12.5-13.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM13.5-14.5×85/105SS

13.5-14.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM14.5-15.5×85/105SS

14.5-15.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM15.5-16.5×85/105SS

15.5-16.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM16.5-17.5×85/105SS

16.5-17.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM17.5-18.5×85/105SS

17.5-18.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM18.5-19.5×85/105SS

18.5-19.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM19.5-20.5×85/105SS

19.5-20.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM20.5-21.5×85/105SS

20.5-21.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM21.5-22.5×85/105SS

21.5-22.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM22.5-23.5×85/105SS

22.5-23.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM23.5-24.5×85/105SS

23.5-24.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe

ROM24.5-25.5×85/105SS

24.5-25.5

35/51

85/105

200 kHz/500 kHz/

2 MHz

Fe/NFe


ROM

3.1-3.6

x

85/105

SS (Sh)

1

2

 

3

4


1. ROM – rotary manual probe for bolt holes testing.

2. Range of tested hole diameters, mm.

3. Probe length, mm, is chosen based on the required working length(“WL”).

4. Probe type designation: “SS”

S” (Split) – Split end delrin housing, “S”(Single)

Probes of standard type are manufactured unshielded. In case a shielded probe is required, when making an order, please indicate the letters ”Sh” (Shielded) at the end of a designation code.