On October 1-4, 2023 OKOndt GROUP attended Railway Interchange 2023 - the largest North American railway event. This time the exhibition took place in Indianapolis, Indiana, USA (Indiana Convention Center) and brought together over 700 exhibitors and more than 8, 000 visitors who are the major influencers in the industry. Thank you to everyone who was with us at the RI 2023!

Eddy current probes

Surface ECP for surface and sub-surface defects detection in aluminum and titanium alloys:

  • is an absolute transducer built according to the Reflection scheme
  • is designed for testing of plane objects or parts with large-radius curvature
  • applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.

The probe sensing element is located form the butt-end relative to the probe X-axis.


Designation

Tip Ø 'D',
mm

Length,
mm

Centre
frequency

Connector

Material

Defects under
paint coating

Subsurface defects

Protective housing

SS1.5M05DA0

5

35

1,5 MHz

Lemo 04

Fe/NFe

up to 0.3 mm

SS650K06DA0

6

35

650 kHz

Fe/NFe

up to 0.5 mm

SS400K07DA0

7

35

400 kHz

Fe/NFe

up to 0.5 mm

SS400K08DA0

8

35

400 kHz

Fe/NFe

up 0.5 mm

SS340K09DA0

9

35

340 kHz

Fe/NFe

up to 1 mm

+

SS170K13DA0

13

35

170 kHz

Fe/NFe

up to 7 mm

+

+

SS50K15DA0

15

50

50 kHz

Fe/NFe

up to 9 mm

+

SS25K33DA0

33

50

25 kHz

Fe/NFe

up to 12 mm

+


SS

1.5M

05D

A

X

1

2

3

4

5


1. SS – (sub surface) probe for surface and sub-surface defects detection.

2. Probe frequency:

HZ” designation for Hz range; “К” designation for kHz range; “М” designation for MHz range.

3. ECP tip diameter, mm.

4. Designation of ECP type "А". “А” – Absolute.

5. ECP modification number.