On October 1-4, 2023 OKOndt GROUP attended Railway Interchange 2023 - the largest North American railway event. This time the exhibition took place in Indianapolis, Indiana, USA (Indiana Convention Center) and brought together over 700 exhibitors and more than 8, 000 visitors who are the major influencers in the industry. Thank you to everyone who was with us at the RI 2023!

Eddy current probes

Sensing element of eddy-current probe coincides with the handle axis

Straight shaft ECP:

  • typical absolute single-coil probe built according to the “Single coil” scheme
  • designed for testing of complex-shape parts with open access
  • applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.

Designation

Tip Ø ‘D’,
mm

Length,
mm

Centre
Frequency

Connector

Material

SU200K3Dx25-105 S

3

105

200 kHz

Microdot

Fe/NFe

SU200K4.5Dx25-105 S

4.5

105

200 kHz

Fe/NFe

SU500K3Dx25-105 S

3

105

500 kHz

Fe/NFe

SU500K4.5Dx25-105 S

4.5

105

500 kHz

Fe/NFe

SU2М2.5Dx25-105 S

2.5

105

2 MHz

NFe

SU2М3Dx25-105 S

3

105

2 MHz

NFe

SU6М2.5Dx25-105 S

2.5

105

6 MHz

NFe



SU

200K

3D

x

25

-

105

S(Sh)

1

2

3

 

4

 

5

6


1. SU – surface probe for surface flaws detection.

2. Probe frequency:

“HZ” designates the Hz range; “К” designates the kHz range; “М” designates the MHz range.

3. Probe tip diameter, mm

4. Shaft size, mm

5. Total probe length, mm. Standard length - of 105 mm (4.1") can be changed upon request.

6. Probe type designation: “S”. “S” – Single coil probe.

Probes of standard type are manufactured unshielded. In case a shielded probe is required, when making an order, please indicate the letters ”Sh” (Shielded) at the end of a designation code.