OKOndt GROUP goes on operating for your non-destructive testing needs. Our team works for you to offer the best NDT solutions of top quality, and impeccable services. In September, the group of our experts attended InnoTrans 2024 and could showcase our latest developments to the visitors, as well as discuss current NDT issues and future partnership

Eddy current probes

Right Angle (L-shaped) ECP for Subsurface Flaws Detection in the Second Layer through the First Layer with Up To 1.5 mm Thickness:

  • is an absolute probe built according to the “Reflection” scheme
  • designed for testing of load-bearing elements under an aircraft skin
  • applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.

Designation

Outer diameter, mm/inch

Drop length, mm

Length, mm/inch

Frequency

Connector

Material

Detected flaws

SSP3K5A7.5Dx3-37ASh

7.5/.3

3/.12

37/1.5

1-25 kHz

Triax Lemo/Fischer

NFe

in aluminum through skin with up to 1.5 mm thickness

SSP3K5A7.5Dx6.4-37ASh

7.5/.3

6.4/.25

37/1.5

1-25 kHz

SSP3K5A7.5Dx12.5-37ASh

7.5/.3

12.5/.5

37/1.5

1-25 kHz


SSP

3K

5A

7.5D

x

3

-

37

A

(Sh)

1

2

3

4

 

5

 

6

7

8


  1. SSP – sub-surface probe for subsurface flaws detection.

  2. Probe frequency:

HZ” designates the Hz range; “К” designates the kHz range; “М” designates the MHz range.

  1. Drop angle of a sensing element to the probe axis “5А” is 90º.

  2. Probe tip diameter, mm

  3. Drop length, mm

  4. Total probe length, mm.

  5. Probe type designation: “А”. АAbsolute.

  6. Sh Shielded sensing element.