Straight Weld Testing ECP:
- is an absolute transducer built according to the “Bridge” scheme
- designed for welds testing in compliance with the ISO 17643 requirements
- applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.
Designation | Tip Ø 'D', | Length, | Frequency, | Connector | Material | Defects under | Subsurface defects |
WLD100K3×.2DA0 | .2/5.1 | 3/75 | 100-1000 | Lemo 04 | Fe | up to 0.3 mm | + |
WLD100K3×.35DA0 | .35/8.9 | 3/75 | 100-1000 | Fe | up to 0.5 mm | + | |
WLD100K3×.43DA0 | .43/10.9 | 3/75 | 100-1000 | Fe | up to 0.5 mm | + | |
WLD100K3×.63DA0 | .63/16 | 3/75 | 100-600 | Fe | up to 1 mm | + | |
WLD100K3×1DA0 | 1/25.4 | 3/75 | 100-600 | Fe | up to 1.5 mm | + |
WLD | 100K | 3 | × | .63D | A | 0 |
1 | 2 | 3 |
| 4 | 5 | 6 |
WLD – weld probe for weld joints testing.
Probe frequency:
“HZ” designates the Hz range; “К” designates the kHz range; “М” designates the MHz range.
Probe length, in. Standard length 3" (75 mm), by default the size is specified in inches. Can be changed upon request.
The probe tip diameter, inches.
Probe type designation "А". “А” – Absolute.
Probe modification number.