OKOndt Group at 20th World Conference on Non-Destructive Testing (20th WCNDT), Incheon, Korea May 2024.

Ultrasonic calibration blocks

  • Application

V2 Calibration Block is designed for verification of the ultrasonic flaw detectors used in the course of welded joints quality control by the UT method. It is DSTU 4002-2000 (ISO 7963, В.S.2704) compliant.

V2 Calibration Block allows:

  • to calibrate the sweep of the flaw detector by the ultrasonic wave velocity for the straight beam piezoelectric transducers
  • to calibrate the sweep of the flaw detector by the ultrasonic wave velocity for the angle beam piezoelectric transducers
  • to set a conditional level of sensitivity of the UT flaw detectors with the straight and angle beam transducers
  • to determine the probe index and X-value of the angle beam transducers
  • to determine the UT wave entry angle in steel.
  • Technical data

  • velocity of the ultrasonic longitudinal waves in the Block material at a frequency of 5.0 MHz and a temperature of (20±5)ºC is (5920±30) m/s
  • velocity of the ultrasonic shear waves in the Block material at a frequency of 5.0 MHz and a temperature of (20±5)ºC is (3255±15) m/s
  • geometrical dimensions of the Block correspond to DSTU 4002-2000 (ISO 7963, B. S. 2704).

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.